Controlled molten-metal pour
Pours a measured mass of molten metal over the specimen at a defined temperature, height and angle.
Mass in g for aluminum, cryolite, copper, iron or mild steel.
Resistance to large molten-metal splashes
ISO 9185 assesses heat penetration through protective-clothing materials during controlled pours of molten metal.
Pours a measured mass of molten metal over the specimen at a defined temperature, height and angle.
Mass in g for aluminum, cryolite, copper, iron or mild steel.
Checks the PVC film beneath the specimen for damage after each pour. ISO 9185:2025 includes iterative and specified-performance-level testing.
Poured mass and corresponding film damage.
Classifies aluminum splashes as code D and iron splashes as code E under ISO 11612:2015.
Minimum metal mass by level.
| Level | Aluminum (D) | Iron (E) |
|---|---|---|
| 1 | 100 g | 60 g |
| 2 | 200 g | 120 g |
| 3 | 350 g | 200 g |
Lightweight foundry protection enhanced with TENCEL™ for comfort.
View fabric →Molten metal + thermal heatThe world reference for proven molten-metal splash protection.
View fabric →Molten steel + ironA lighter, more breathable answer to severe steel and iron exposure.
View fabric →