ISO 15025
Tests surface ignition (A1) and additional edge ignition (A2) on materials and structural seams after cleaning.
Afterflame ≤ 2 s and afterglow ≤ 2 s. No flaming or molten debris; the surface test also checks holes and flame reaching specimen edges.